logo
제품 소개독성물질 검사 키트

High Ssensitivity Microcystins ELISA Test Kit

제가 지금 온라인 채팅 해요

High Ssensitivity Microcystins ELISA Test Kit

High Ssensitivity Microcystins  ELISA Test Kit
High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit High Ssensitivity Microcystins  ELISA Test Kit

큰 이미지 :  High Ssensitivity Microcystins ELISA Test Kit

제품 상세 정보:
원래 장소: 중국
브랜드 이름: Chenhui
모델 번호: CH98018
결제 및 배송 조건:
최소 주문 수량: 1키트
가격: negotiable
포장 세부 사항: 컬러 포장
배달 시간: 5-8 근무일
지불 조건: t/t
공급 능력: 1000개 장비

High Ssensitivity Microcystins ELISA Test Kit

설명
빠른: <30분 높은 회복: 80-105%
탐지 시간: 1 시간 저장 온도: 2-8 ° C
사양: 96T 선형 간격: 0.02ng/ml
강조하다:

high sensitivity microcystins ELISA kit

,

microcystins toxin test kit

,

ELISA test kit for toxins

 

Microcystins ELISA Test Kit

 

CH 98018

         

         

Product Description

 

High Ssensitivity Microcystins  ELISA Test Kit 0     The Microcystins ELISA is an immunoassay for the quantitative and sensitive congener-independent detection of Microcystins and Nodularins in water samples.

 

Sample Collection and Handling

Collect water samples in glass or PETG containers and test within 24 hours. Use of other types of plastic collection and/or storage containers may result in adsorptive loss of Microcystins, producing inaccurate (falsely low) results. Drinking water samples should be treated with sodium thiosulfate immediately after collection . If samples must be held for longer periods (up to 5 days), samples should be stored refrigerated. For storage periods greater than 5 days, samples should be stored frozen.

If total Microcystins concentration (free and cell bound) is required, an appropriate cell lysing procedure must be performed prior to analysis.

Note: The use of sonication in cell lysing can negatively affect toxin concentrations, producing falsely low sample results.

Samples may be filtered prior to analysis using glass fiber filters. The use of alternate filter types (non-glass fiber filters) may produce falsely low sample results, as Microcystins may bind to the filter material, removing it from the sample. Also, please note that some glass fiber filters are manufactured using a process which may cause interference which would cause inaccurate (falsely high) results. To avoid this potential bias in sample results, a total volume of at least 10 mL should be passed through the glass fiber filter, with the first 5 mL of filtered sample being discarded and the second 5 mL collected for testing . If determining total Microcystins concentration, samples should be lysed prior to filtration to prevent the removal of cell-bound Microcystins, which would cause inaccurate (falsely low) results.

High Ssensitivity Microcystins  ELISA Test Kit 1

연락처 세부 사항
Maoming Chenhui Biotechnology Co., Ltd.

담당자: Tina

전화 번호: +8615818799493

회사에 직접 문의 보내기 (0 / 3000)